show faults¶
Displays basic diagnostic information for Comtech EF Data and Sea Tel devices.
Command availability¶
CLI resource: port
Device makes: Comtech EF Data, Sea Tel
Lantronix Local Managers: All
LMS offerings: All
Syntax¶
For more detailed information on system faults, use the verbose option (-v) on the show faults command. The verbose command will display the DAC status words and their translation.
Usage¶
[admin@LantronixLM (port1/3)]# show faults
PCU Status Bit 0, Satellite out of range, PCU Error, AZ Reference Error, Polang Drive Off, Band Tone Off, Band 13V, AUX is off, Band C, Local-RF 18V, Local Tone Off, No Force NID, FEC-SCPC
[admin@LantronixLM (port1/3)]# show faults -v
Word 1: 0x40 (01000000) 64 '@'
Word 2: 0x40 (01000000) 64 '@'
Word 3: 0x68 (01101000) 104 'h'
Word 4: 0x48 (01001000) 72 'H'
Remote RF: 0x40 (01000000) 64 '@'
Local RF: 0x67 (01100111) 103 'g'
TDisp: 0x00 (00000000) 0 '\u0000'
Satellite out of range, PCU Error, AZ Reference Error, Polang Drive Off, Band Tone Off, Band 13V, AUX is off, Band C, Local-RF 18V, Local Tone Off, No Force NID, FEC-SCPC
History¶
3.5 - This command was introduced.