Skip to content

show rule

Displays rules that can be applied to monitors that initiate alerting and action.

Command availability

CLI resource: system

Lantronix system: All

LMS offerings: All

Syntax

show rule <"rulename" | *>

Specify the name of a rule, or use the * character to show all rules defined on the system.

Usage

[admin@LantronixLM]# show rule modemLineDisconnected
rule modemLineDisconnected
action alarm MODEM_LINE_DISCONNECTED
conditions
modem.response equals "NO DIALTONE" :2i OR
modem.response equals "NO LINE" :2i OR
modem.response matches "1\.40\s+OK" :2i
exit
exit

In the Lantronix web interface

Inventory > group page > Automation > Rules - specific to this inventory group

Inventory > Local Manager page > Automation > Rules - specific to this system

History

1.1 - This command was introduced.

Related commands