XML Reference¶
Index of XML Groups and Items¶
Click here to view all groups and items...
configgroup Access Point¶
The XML instance must be "ap0".
These settings pertain to the Access Point in the device. Changes take effect immediately. After saving the changes, re-establish any connections to the Access Point.
configitem SSID¶
value¶
SSID may contain up to 32 characters.
SSID may contain one or more Directives of the form %<option>.
Blank the value to restore the default.
Directives:
- %s (serial number)
- %<n>s (first <n> characters of serial number)
- %-<n>s (last <n> characters of serial number)
- Other use of % is not supported.
configitem Guest¶
value¶
Guest may be "Enabled" or "Disabled".
"Enabled" allows clients to discover our SSID via a passive scan.
"Disabled" causes this device to ignore probe requests with the wildcard SSID.
In either case this device responds to directed scans that contain our SSID.
configitem Channel¶
value¶
Blank the value for "<Auto>".
Channel configured here is applicable only if wlan0 is down or disabled.
If wlan0 is up, its associated Access Point will set the channel, and ap0 must also operate on that same channel.
NOTE: If the AP channel is not valid for the configured radio band, a valid channel will automatically be selected when the AP is started.
configitem Auto Channel Scan Interval¶
value¶
Auto Channel Scan Interval has units of minutes, hours, and/or days.
configitem Suite¶
value¶
Suite may be "None", "WPA" or "WPA2".
configitem Encryption¶
value¶
Encryption may contain combinations of "CCMP" or "TKIP".
configitem Passphrase¶
value¶
Passphrase may contain up to 63 characters.
configitem Mode¶
value¶
Mode may be "Always Up", "Triggered", "Initial Trigger" or "Initially Up".
"Always Up" brings ap0 up unconditionally.
"Triggered" waits for CPM Role "AP Trigger" to become active. Then ap0 stays up according to Uptime.
"Initial Trigger" waits for CPM Role "AP Trigger" to become active. Then ap0 stays up indefinitely.
"Initially Up" comes up upon bootup, but only stays up according to Uptime.
configitem Uptime¶
value¶
Uptime has units of seconds, minutes, and/or hours.
Uptime designates the time that ap0 will remain up after it has been triggered.
configitem DNS Redirect¶
value¶
DNS Redirect may contain up to 128 characters.
The DNS Redirect name will map to the IP address of the Interface. It may contain upper case, but note that DNS names are case insensitive.
NOTE: the DNS Redirect will not work if Interface ap0 has either Primary DNS or Secondary DNS configured; these override the device internal simple DNS.
Blank to restore the default.
configgroup Clock¶
These settings pertain to the Clock settings for keeping time.
configitem Source¶
value¶
Source may be "Manual" or "NTP".
configitem UTC Offset¶
value¶
UTC Offset is allowed to have negative values.
UTC Offset has units of minutes.
UTC Offset must be in the range of -1440 to 1440, and be a multiple of 15 minutes.
Lists of common time zones and corresponding UTC Offset can be found at several websites, including "http://www.iana.org/time-zones".
configgroup CPM¶
These settings pertain to the Configurable Pin Manager (CPM).
NOTE: Changes may take effect immediately or require reboot, so you should reboot after changing CPM Role configurations.
configitem Role¶
"AP Trigger" turns on ap0 if Mode is "Triggered" or "Initial Trigger".
"Ethernet Link" is Link UP while eth0 is up.
"GSPI Slave Interrupt" signals new data or space available.
"HTTP Server Trigger" turns on HTTP Server if Mode is "Triggered".
"Keep AWAKE" Input keep AWAKE CP role.
"Line 1 DSR" read by application.
"Line 1 DTR" set by application.
"Modbus Input 1" can be read by Modbus TCP.
"Modbus Input 2" can be read by Modbus TCP.
"Modbus Input 3" can be read by Modbus TCP.
"Modbus Input 4" can be read by Modbus TCP.
"Modbus Output 1" can be written by Modbus TCP.
"Modbus Output 2" can be written by Modbus TCP.
"Modbus Output 3" can be written by Modbus TCP.
"Modbus Output 4" can be written by Modbus TCP.
"Radio Trigger" turns on radio if Mode is "Triggered".
"SPI.CS" pin is used when SPI State is "Enabled".
"SPI.MISO" pin is used when SPI State is "Enabled".
"SPI.MOSI" pin is used when SPI State is "Enabled".
"SPI.SCK" pin is used when SPI State is "Enabled".
"USB Host Overcurrent" pin is used when USB Host State is "Enabled".
"USB Host Power Enabled" output active to enable power output to USB device.
"User Data Updated" is active when user data changes, till Acknowledge action.
"WLAN Active" is active while wlan0 is up.
value CP¶
Blank the value for "<No CP Selected>".
This is the number of the Configurable Pin (CP) assigned to the role.
value State¶
State may be "Enabled" or "Disabled".
"Enabled" allows the application to use the designated Configurable Pin.
Note that some Roles (those containing a ".") are bundled into a group. Enabling / Disabling any one of them also Enables / Disables the rest of the Roles in the same Group.
value Assert¶
Assert may be "High" or "Low".
Assert reflects the logical polarity of this Configurable Pin.
"High" means that a logical "1" corresponds to a voltage high condition on the pin.
"Low" means that a logical "1" corresponds to a voltage low condition on the pin.
value Mode¶
Mode may be "Push-Pull" or "Weak Pullup".
For a high impedance input, select "Push-Pull".
configgroup Ethernet¶
The XML instance must be "eth0".
These settings pertain to the Ethernet link in the device. Changes take effect immediately. After saving the changes, re-establish any connections to the Ethernet link.
configitem RMII Mode¶
value¶
RMII Mode may be "PHY" or "Switch".
RMII Mode specifies what type of external device is attached to the RMII interface.
When in PHY mode, the RMII interface is connected to an external PHY. The PHY is managed over the MDIO bus, and the user can specify settings such as Speed and Duplex.
When in Switch mode, the RMII interface is connected to a port of an external switch chip in a MAC-to-MAC configuration. The RMII interface is forced to 100 Mbps with Full Duplex, and the MDIO bus is not used. The switch chip must have its side of the RMII interface strapped to 100 Mbps with Full Duplex.
configitem PHY Address¶
value¶
PHY Address is the address of the external Ethernet PHY device on the MDIO bus. Most PHYs support address 0, but can generally be configured to something else with hardware strapping.
configitem Speed¶
value¶
Speed may be "Auto", "10" or "100".
configitem Duplex¶
value¶
Duplex may be "Half" or "Full".
configitem MDIO Logging¶
value¶
MDIO Logging may be "Enabled" or "Disabled".
MDIO Logging is useful for debugging PHY configuration issues.
When Enabled, each access to PHY registers over the MDIO bus will be logged. Also, it will dump the first 32 PHY registers to the log every 15 seconds.
configitem EAP Authentication¶
value¶
EAP Authentication may be "Enabled" or "Disabled".
configitem IEEE 8021X¶
value¶
IEEE 8021X may be "EAP-TLS", "EAP-TTLS", "PEAP" or "FAST".
configitem Username¶
value¶
Username may contain up to 63 characters.
configitem Password¶
value¶
Password may contain up to 63 characters.
configitem Credentials¶
value¶
Credentials may contain up to 30 characters.
configitem EAP-TTLS Option¶
value¶
EAP-TTLS Option may be "EAP-MSCHAPV2", "MSCHAPV2", "MSCHAP", "CHAP", "PAP" or "EAP-MD5".
configitem PEAP ver¶
value¶
PEAP ver may be "0" or "1".
configitem PEAP Option¶
value¶
PEAP Option may be "EAP-MSCHAPV2", "EAP-MD5" or "EAP-TLS".
configitem PEAP Credentials¶
value¶
PEAP Credentials may contain up to 30 characters.
configitem FAST Option¶
value¶
FAST Option may be "MD5", "MSCHAPV2" or "GTC".
configgroup HTTP Server¶
These settings pertain to the HTTP Server. Changes will take effect after reboot.
configitem Mode¶
value¶
Mode may be "Disabled", "Enabled" or "Triggered".
"Disabled" prevents HTTP from operating on any port.
"Enabled" allows the HTTP Server to operate.
"Triggered" waits for CPM Role "HTTP Server Trigger" to become active. Then the HTTP Server stays up indefinitely.
configitem Port¶
value¶
Enter 0 for "<None>".
The default Port can be overridden.
configitem Secure Port¶
value¶
Enter 0 for "<None>".
The default Secure Port (TLS) can be overridden.
configitem Secure Credential¶
value¶
Secure Credential may contain up to 30 characters.
The Secure Credential specifies the name of the TLS Server Credential to be used for the secure connection.
configitem Authentication Timeout¶
value¶
Authentication Timeout has units of minutes, hours, and/or days.
The Authentication Timeout applies only if Digest authentication is being used.
configitem Inactivity Timeout¶
value¶
Inactivity Timeout has units of seconds, minutes, and/or hours.
The Inactivity Timeout applies only if the Application "HTTP Server" is enabled in the Power settings.
The HTTP Server will hold power on this long after it completes a request.
configitem Access-Control-Allow-Origin¶
value¶
Access-Control-Allow-Origin may contain up to 50 characters.
Access-Control-Allow-Origin is a newer security mechanism supported by some browsers. This feature is also referred to as CORS.
When blank (by default), CORS is disabled.
Set a name to enable CORS. Use "*" for wildcard, but beware this exposes the device to Cross-Site Request Forgery (CSRF).
configgroup HTTP Server Security¶
These settings pertain to the HTTP Server Security. Changes take effect immediately.
configitem Access Control¶
*The XML *instance may range from 1 to 9.
value URI¶
URI may contain up to 255 characters.
The HTTP Server can be configured with many different authentication directives. The authentication is hierarchical in that any URI can be given an authentication directive in order to override a parent URI authentication directive.
The URI must begin with /
.
For example, create URI "/Welcome", then place your "hello.html" file in directory "/http/Welcome/", finally point your browser to "<device IP address>/Welcome/hello.html" to experiment with the authorization levels.
The following URIs are built into the server:
"/action/status" Action Web API
"/ajax" Web Manager helper
"/export/config" Config export Web API
"/export/status" Status export Web API
"/import/config" Config import Web API
"/wm/firmware_upgrade" Web Manager upgrade firmware
"/wm/fs/copy" Web Manager copy file
"/wm/fs/mkdir" Web Manager make directory
"/wm/fs/rename" Web Manager rename file
"/wm/fs/rm" Web Manager remove file
"/wm/fs/rmdir" Web Manager remove directory
"/wm/fs/upload" Web Manager upload file
"/fs" File System Web API
"/logout" Digest authentication
"/mux_http" Mux HTTP listener
"/tlog" Trouble log
"/upgrade" Firmware Upgrade Web API
"/wm/pkcs12_upload" Web Manager PKCS12 upload
value AuthType¶
AuthType may be "None", "Basic", "Digest", "TLS", "TLS Basic" or "TLS Digest".
"None" provides no authentication.
"Basic" encodes passwords using Base64.
"Digest" hashes passwords using MD5.
"TLS" encrypts data but provides no authentication.
"TLS Basic" encrypts data and encodes passwords using Base64.
"TLS Digest" encrypts data and hashes passwords using MD5.
value User Level¶
User Level may be "User", "Tech", "Admin" or "None".
"User" provides access to all users.
"Tech" provides users with Privilege "Tech" access only if one or more of their Zones are configured here. Users with Privilege "Admin" also have access.
"Admin" provides access only to users with Privilege "Admin".
"None" provides access to no users.
value Zones¶
Zones may contain combinations of "A", "B", "C", "D" or "E".
Select the Zones to be provided Tech access to this URI.
The meaning of the zones is determined by how you define them here. For example, say you define zones A and B via Access Controls:
- /Toasters Tech A
- /Blenders Tech B
Then over in Users you may reference zones:
- admin Admin (has access to everything)
- barry Tech A (has access to Toasters)
- cindy Tech B (has access to Blenders)
- david Tech A B (has access to Toasters and Blenders)
- edwin User (has access to neither)
configitem Config¶
The XML instance may range from 1 to 9.
value Group¶
Group may contain up to 30 characters.
The Group identifies the configuration group to which permissions apply. The authentication is hierarchical, similar to the access control URI.
The wildcard "" in Group* applies to all groups except "User" and "HTTP Server Security" which have their own rules.
value User Level¶
User Level may be "User", "Tech", "Admin" or "None".
"User" permits all users to change settings.
"Tech" permits users with Privilege "Tech" to change settings in the Group if one or more of their Zones are configured here. Users with Privilege "Admin" may also change settings.
"Admin" permits users with Privilege "Admin" to change settings in the Group.
"None" denies changes in the Group by any user.
value Zones¶
Zones may contain combinations of "A", "B", "C", "D" or "E".
Select the Zones to be provided Tech permission to this Group.
configitem Status¶
The XML instance may range from 1 to 9.
value Group¶
Group may contain up to 30 characters.
The Group identifies the status group to which permissions apply. The authentication is hierarchical, similar to the access control URI.
The wildcard "" in Group* applies to all groups.
value Optional Item¶
Optional Item may contain up to 30 characters.
If not blank, the Optional Item name further narrows permissions.
value Optional Action¶
Optional Action may contain up to 30 characters.
If not blank, the Optional Action name further narrows permissions.
value User Level¶
User Level may be "User", "Tech", "Admin" or "None".
"User" permits all users to perform actions.
"Tech" permits users with Privilege "Tech" to perform actions in the Group if one or more of their Zones are configured here. Users with Privilege "Admin" may also perform actions.
"Admin" permits users with Privilege "Admin" to perform actions in the Group.
"None" denies actions in the Group by any user.
value Zones¶
Zones may contain combinations of "A", "B", "C", "D" or "E".
Select the Zones to be provided Tech permission to this Group.
configgroup Interface¶
The XML instance may be "ap0", "eth0" or "wlan0".
These settings pertain to the Network Interface on the device. To see the effect of these selections after a reboot, view the corresponding Status. Changes will take effect after reboot or wake from standby.
When ap0 is enabled, DHCP Server will assign IP addresses to ap0's clients. DHCP Server manages up to 6 simultaneous clients. (Only 5 if wlan0 is enabled.)
configitem State¶
value¶
State may be "Enabled" or "Disabled".
"Enabled" allows the Interface to operate.
configitem Hostname¶
value¶
Hostname may contain up to 63 characters.
Hostname must begin with a letter or number, continue with letter, number, or hyphen, and must end with a letter or number.
If DHCP Client is "Enabled", the Hostname is sent to the remote DHCP Server and may figure into the address assignment. See also Domain which is appended to the Hostname when sending to the remote DHCP Server.
This setting is not applicable to ap0.
configitem Priority¶
value¶
When performing TCP or UDP connect, the Interface with Priority 1 will be attempted first, 2 will be attempted second, etc.
By default all Interfaces have Priority 1 and Ethernet interfaces are attempted before WLAN.
configitem MSS¶
value¶
MSS has units of bytes.
The Maximum Segment Size (MSS) applies to TCP connections on the Interface. This can be useful to avoid fragmentation over the network, which may be required because this device does not perform reassembly.
configitem DHCP Client¶
value¶
DHCP Client may be "Enabled" or "Disabled".
When "Enabled", any configured IP Address or Default Gateway will be ignored. DHCP Client will auto-discover and eclipse those configuration items. Hostname and / or Default Gateway is sent to the remote DHCP Server and may figure into the address assignment.
When DHCP Client fails to discover an IP Address, a new address will automatically be generated using AutoIP. This address will be within the 169.254.x.x space.
This setting is not applicable to ap0.
configitem DHCP Server¶
value¶
DHCP Server may be "Enabled" or "Disabled".
configitem IP Address¶
value¶
IP Address may contain up to 31 characters.
IP Address may be entered alone, in CIDR form, or with an explicit mask:
- 192.168.1.1 (default mask)
- 192.168.1.1/24 (CIDR)
- 192.168.1.1 255.255.255.0 (explicit mask)
The IP Address will be displayed always in CIDR, the canonical form.
configitem Default Gateway¶
value¶
Default Gateway may contain up to 15 characters.
For ap0, which has a DHCP Server, the Default Gateway (if present) is placed into DHCP response option 3.
Other interfaces refer to the Default Gateway only if DHCP Client is disabled.
configitem Domain¶
value¶
Domain may contain up to 128 characters.
NOTE: A fully qualified domain name must end with a period, for example, "lantronix.com."; a partial Domain will not have a trailing"." and is not fully qualified.
If DHCP Client is "Enabled", it concatenates the Hostname with Domain and requests the DHCP server to update the DNS A and PTR RRs.
This setting is not applicable to ap0.
configitem Primary DNS¶
value¶
Primary DNS may contain up to 15 characters.
For ap0, which has a DHCP Server, the Primary DNS (if present) is placed into DHCP response option 6. If neither the Primary DNS nor Secondary DNS is present in the ap0 configuration, the DHCP Server offers its own simple DNS.
Other interfaces refer to the Primary DNS only if DHCP Client is disabled.
The Primary DNS is the first choice when performing a Domain Name lookup.
configitem Secondary DNS¶
value¶
Secondary DNS may contain up to 15 characters.
For ap0, which has a DHCP Server, the Secondary DNS (if present) is placed into DHCP response option 6. If neither the Primary DNS nor Secondary DNS is present in the ap0 configuration, the DHCP Server offers its own simple DNS.
Other interfaces refer to the Secondary DNS only if DHCP Client is disabled.
The Secondary DNS is the second choice when performing a Domain Name lookup.
configitem IPv6 State¶
value¶
IPv6 State may be "Enabled" or "Disabled".
configitem DHCPv6 Client¶
value¶
DHCPv6 Client may be "Enabled" or "Disabled".
DHCPv6_Client: Enables the stateful address autoconfiguration of IPv6 When it is enabled, device will start DHCPv6 client service & get the IPv6 address from the DHCPv6 serevr as per RFC-3315. (https://tools.ietf.org/html/rfc3315)
configitem IPv6 Auto Configuration¶
value¶
IPv6 Auto Configuration may be "Enabled" or "Disabled".
IPv6 Auto Configuration: Enables the stateless adddress autoconfiguration of IPv6 When it is enabled, device will generate its own IPv6b address from prefix in Router Advertisements & its MAC address as per RFC-4862 (https://tools.ietf.org/html/rfc4862)
configitem IPv6 Address¶
value¶
IPv6 Address may contain up to 42 characters.
IPv6 Address: The preferred form is x:x:x:x:x:x:x:x, where the 'x's are one to four hexadecimal digits of the eight 16-bit pieces of the address as per RFC-4291 (https://tools.ietf.org/html/rfc4291)
Examples: ABCD:EF01:2345:6789: ABCD:EF01:2345:6789, 2001:DB8:0:0:8:800:200C:417A
It supports compressed form of IPv6 Addresses
configitem IPv6 Default Gateway¶
value¶
IPv6 Default Gateway may contain up to 42 characters.
IPv6 Default Gateway: is used only if DHCPv6 Client is disabled, and provides the IPv6 Address of the router.
This setting is not applicable to ap0.
configitem IPv6 Primary DNS¶
value¶
IPv6 Primary DNS may contain up to 42 characters.
IPv6 Primary DNS: is the first choice when performing IPv6 Domain Name lookup.
This setting is not applicable to ap0.
configitem IPv6 Secondary DNS¶
value¶
IPv6 Secondary DNS may contain up to 42 characters.
IPv6 Secondary DNS: is the second choice when performing IPv6 Domain Name lookup.
This setting is not applicable to ap0.
configitem DHCP IP Address Range¶
value Start¶
Start may contain up to 15 characters.
Start is the lowest IP address that the DHCP server may assign.
value End¶
End may contain up to 15 characters.
End is the highest IP address that the DHCP server may assign.
configitem Name¶
value¶
Name may contain up to 15 characters.
configgroup Line¶
The XML instance may be "1", "gSPI_1", "gSPI_2", "gSPI_3", "gSPI_4", "SPP_1", "SPP_2", "SPP_3", "CDC_ACM", "HOST_CDC_ACM", "Virtual_1" or "Virtual_2".
These settings pertain to the Serial Line. Changes take effect immediately.
configitem Name¶
value¶
Name may contain up to 25 characters.
The Name is for display purposes only.
configitem Interface¶
value¶
Interface may be "RS232", "RS485 Half-Duplex" or "RS485 Full-Duplex".
configitem Tx to Rx delay¶
value¶
Tx to Rx delay has units of milliseconds.
The Tx to Rx delay can be specified for the RS485 Half-Duplex (2 wire) mode. This is the delay after sending the last character out the wire, before switching to receive mode.
configitem State¶
value¶
State may be "Enabled" or "Disabled".
"Enabled" allows the Serial Line to operate.
configitem Protocol¶
value¶
Protocol may be "BLE Beacon Scanner", "Command Line", "ConsoleFlow Interface", "Modbus ASCII", "Modbus RTU", "Modem Emulation", "Monitor", "Mux", "None", "Trouble Log" or "Tunnel".
Protocol selects the application to connect to the Line.
"BLE Beacon Scanner" scans for BLE Beacons and outputs them on the line.
"Command Line" sets up a user interface containing commands to show device status and to change configuration. Simply paste in XML configuration to apply its settings to the device.
"ConsoleFlow Interface" provides a command interface to the ConsoleFlow serial API.
"Modbus ASCII" talks to programmable logic controllers via ASCII with checksum.
"Modbus RTU" talks to programmable logic controllers via binary with CRC.
"Modem Emulation" implements legacy AT commands.
"Monitor" captures selected data.
"Mux" provides commands for sending / receiving data on multiple network connections.
"None" enables Line action commands.
"Trouble Log" sets up an output-only message log on the device.
"Tunnel" sets up the Line to work with the Tunnel application. See the Tunnel configuration options for details.
configitem Baud Rate¶
value¶
Baud Rate has units of bits per second.
When specifying a Custom baud rate in the Web Manager, select 'Custom' from the drop down list and then enter the desired rate in the text box.
configitem Parity¶
value¶
Parity may be "None", "Even" or "Odd".
configitem Data Bits¶
value¶
Data Bits may be "7" or "8".
configitem Stop Bits¶
value¶
Stop Bits may be "1" or "2".
configitem Flow Control¶
value¶
Flow Control may be "None", "Hardware" or "Software".
configitem Xon Char¶
value¶
Xon Char may contain one byte.
A control character <control>J, for example, counts as one.
A control character can be input in alternate forms:
- \17 (decimal)
- 0x11 (hexadecimal)
- <control>Q (control)
configitem Xoff Char¶
value¶
Xoff Char may contain one byte.
A control character <control>J, for example, counts as one.
A control character can be input in alternate forms:
- \17 (decimal)
- 0x11 (hexadecimal)
- <control>Q (control)
configitem Gap Timer¶
value¶
Gap Timer has units of milliseconds.
Blank the value for "<Four Character Periods>".
The driver forwards received serial bytes after the Gap Timer delay from the last character received. By default, the delay is four character periods at the current baud rate (minimum 1 ms) for those Line types that support adjustable baud rates.
configitem Threshold¶
value¶
Threshold has units of bytes.
The driver will forward received characters after Threshold bytes have been received.
configitem Push¶
value¶
Push may contain up to 2 bytes.
A control character <control>J, for example, counts as one.
If defined, the driver will forward received characters after the Push sequence of characters is received.
configgroup Power¶
These settings pertain to Power levels required by the device. Changes take effect immediately.
configitem Dynamic Power Mode¶
value¶
Dynamic Power Mode may be "Disabled" or "Standby".
"Disabled" prevents the device from powering down.
"Standby" powers down as much as is possible, including the CPU. System runtime state is not preserved.
configitem Time Powered Up¶
value¶
Time Powered Up has units of seconds, minutes, hours, and/or days.
The device holds power on for Time Powered Up duration.
After the Time Powered Up duration, power might continue to be held on for other reasons:
If WKUP Pin is "Level High", power will be held on as long as the WKUP level is high.
Any enabled Application can hold power on.
configitem Application¶
If any Application is "Enabled", the application may hold power on longer or wake up sooner. This provides a mechanism to allow an application to be in an appropriate state for graceful shutdown.
"Command Line" holds power on till the last CLI user exits.
"HTTP Server" holds power up during each HTTP client operation and for a configurable time afterward.
"Keep AWAKE CP Role" holds power on till Keep AWAKE CP Role pin goes active.
"Tunnel Accept" holds power up while any Tunnel Accept connection is open.
"Tunnel Connect" holds power up while any Tunnel Connect connection is open.
value State¶
State may be "Enabled" or "Disabled".
"Enabled" allows this Application to hold power on.
configitem WKUP Pin¶
value¶
WKUP Pin may be "Disabled" or "Falling Edge".
WKUP Pin selects the role of the WKUP pin in powering up or staying up.
"Disabled" means the WKUP Pin is ignored. Power up will happen after Maximum Time Powered Down or earlier if called for by an enabled Application.
"Falling Edge" means the system will power up on the falling edge of WKUP. Power up can also happen after Maximum Time Powered Down or earlier if called for by an enabled Application.
configitem Maximum Time Powered Down¶
value¶
Maximum Time Powered Down has units of seconds, minutes, hours, and/or days.
The device wakes up after being down Maximum Time Powered Down.
The device may wake up earlier if WKUP Pin sees a "Falling Edge".
The device may also wake up earlier if called for by an enabled Application.
configgroup Radio¶
These settings pertain to the Radio.
Any change to these settings requires a reboot to take effect.
configitem Mode¶
value¶
Mode may be "Disabled", "Enabled", "Triggered" or "Initial Delay".
"Disabled" holds the Radio in low power.
"Enabled" allows the Radio to operate.
"Triggered" waits for CPM Role "Radio Trigger" to become active. Then the Radio stays up indefinitely.
NOTE: If Radio is disabled or not yet triggered, this inhibits both ap0 and wlan0 from operating.
configitem Band¶
value¶
Band may be "Dual", "2.4 GHz Only" or "5 GHz Only".
Selects the band on which the radio will operate.
NOTE: If the configured AP channel is not valid for the radio band, a valid channel will automatically be selected each time the AP is started.
configitem Antenna Selection¶
value¶
Antenna Selection may be "Auto", "1" or "2".
"Auto" allows the Radio to select the best antenna at any time.
"1" forces the Radio to use only antenna 1.
"2" forces the Radio to use only antenna 2.
configitem Antenna 1 Supports¶
value¶
Antenna 1 Supports may be "WiFi" or "Bluetooth".
configitem Keep Alive¶
value¶
Keep Alive may be "Enabled" or "Disabled".
"Enabled" causes a Null-Function Data frame to be sent on wlan0 once per second to keep the link up.
configitem Max Volley Delay¶
value¶
Max Volley Delay has units of seconds and/or minutes.
While wlan0 is Disconnected, it scans in turn for each WLAN Profile. One scan per profile comprises a volley. The intervolley delay is doubled after failure to join, subject to the Max Volley Delay.
WARNING: Short delay will compromise ap0 performance; ap0 cannot communicate while the radio is scanning.
configitem Log¶
value¶
Log may be "Enabled" or "Disabled".
"Enabled" causes radio log messages to be placed in the Trouble Log. This facilitates troubleshooting but may compromise performance.
configitem Event Log¶
value¶
Event Log may be "Enabled" or "Disabled".
"Enabled" causes radio events to be interpreted and displayed in the Trouble Log. [For diagnostic purposes.]
configitem Roaming¶
value State¶
State may be "Enabled" or "Disabled".
value Scan Period¶
Scan Period has units of seconds and/or minutes.
Scan Period is the time between scans looking for a roaming candidate.
value Band <instance> Trigger Delta¶
<instance> may be "2.4GHz" or "5GHz".
Trigger Delta has units of dBm.
A device with RSSI Trigger Delta higher than the current Access Point is a roaming candidate.
value Band <instance> RSSI Floor¶
<instance> may be "2.4GHz" or "5GHz".
RSSI Floor is allowed to have negative values.
RSSI Floor has units of dBm.
When the signal drops below the RSSI Floor, the radio attempts to roam.
configitem Scanning¶
value RSSI Floor¶
RSSI Floor is allowed to have negative values.
RSSI Floor has units of dBm.
When scanning, any signal below the RSSI Floor is omitted.
NOTE: Roaming will not see the omitted signals.
configitem Initial Delay¶
value Minimum¶
Minimum has units of seconds, minutes, and/or hours.
To avoid many devices communicating at the same time after Power On, set an Initial Delay range. Each device will have a random delay uniformly distributed between Minimum and Maximum.
value Maximum¶
Maximum has units of seconds, minutes, and/or hours.
To avoid many devices communicating at the same time after Power On, set an Initial Delay range. Each device will have a random delay uniformly distributed between Minimum and Maximum.
configgroup SPI¶
These settings pertain to the Serial Peripheral Interface (SPI) Bus Master device.
Most changes take effect immediately. However, if the device State has been "Enabled", then changing its Protocol or State may require a reboot.
NOTE: High speeds are only available when CS Active is "Low", Idle Clock Level is "Low", and Clock Edge is "First".
configitem Name¶
value¶
Name may contain up to 25 characters.
The Name is for display purposes only.
configitem State¶
value¶
State may be "Enabled" or "Disabled".
"Enabled" enables the SPI.
"Disabled" disables the SPI.
Changing State from "Enabled" to "Disabled" requires a reboot.
configitem Protocol¶
value¶
Protocol may be "Monitor" or "None".
Protocol selects the application to connect to the SPI.
Changing the Protocol of a device requires a reboot only if the device State has been "Enabled" at least once since boot.
"Monitor" captures selected data.
configitem Target Speed¶
value¶
Target Speed has units of Hz.
Blank the value for "<Minimum>".
Target Speed selects the target clock speed of the SPI.
The Target Speed may be lowered to the closest Operating Speed capability of the device. If so, a warning will be noted.
configitem CS Active¶
value¶
CS Active may be "Low" or "High".
CS Active controls the polarity of the SPI Chip Select.
"Low" means CS will idle at a high level and be active when low.
"High" means CS will idle at a low level and be active when high.
configitem Idle Clock Level¶
value¶
Idle Clock Level may be "Low" or "High".
Idle Clock Level, also known as Clock Polarity or CPOL, selects the level of the clock when idle:
"Low" means the idle clock is at a low level. This is equivalent to CPOL=0.
"High" means the idle clock is at a high level. This is equivalent to CPOL=1.
configitem Clock Edge¶
value¶
Clock Edge may be "First" or "Second".
Clock Edge, also known as Clock Phase or CPHA, selects the clock edge for latching data:
"First" means each bit is latched on the first edge of the clock. This is equivalent to CPHA=0. When Idle Clock Level is "Low", data is latched on the rising edge. When Idle Clock Level is "High", data is latched on the falling edge.
"Second" means each bit is latched on the second edge of the clock. This is equivalent to CPHA=1. When Idle Clock Level is "Low", data is latched on the falling edge. When Idle Clock Level is "High", data is latched on the rising edge.
configitem Bits Per Word¶
value¶
Bits Per Word may be "8" or "16".
Bits Per Word selects the number of bits per word of transfer.
configitem First Transfer¶
value¶
First Transfer may be "Most Significant Bit" or "Least Significant Bit".
First Transfer selects the first transfer bit of each word.
configgroup User¶
These settings pertain to each User on the device.
configitem Password¶
value¶
Password may contain up to 32 characters.
configitem Privilege¶
value¶
Privilege may be "User", "Tech" or "Admin".
Sets the user Privilege which governs what they can do.
"User" has access only to areas with User Level set to "User".
"Tech" has access only to areas with User Level set to "User" or with User Level set to "Tech" within the designated Zones.
"Admin" has access to all except areas with User Level set to "None".
configitem Zones¶
value¶
Zones may contain combinations of "A", "B", "C", "D" or "E".
Zones designate areas that a "Tech" has access to.
The meaning of the zones is determined by how you define them over in HTTP Server Security Access Controls. For example, say you define zones A and B via Access Controls:
- /Toasters Tech A
- /Blenders Tech B
Then here you may reference zones:
- admin Admin (has access to everything)
- barry Tech A (has access to Toasters)
- cindy Tech B (has access to Blenders)
- david Tech A B (has access to Toasters and Blenders)
- edwin User (has access to neither)
configgroup WLAN Profile¶
These settings pertain to a WLAN Profile on the device.
If wlan0 connects to an access point on a different wireless channel, a current connection to ap0 may be dropped due to the channel change. Reconnect to ap0 in order to continue access to the device.
configitem Basic¶
value Network Name¶
Network Name may contain up to 32 characters.
value State¶
State may be "Enabled" or "Disabled".
"Enabled" allows this profile to be used.
"Disabled" prevents this profile form being used.
configitem Security¶
value Suite¶
Suite may be "None", "WEP", "WPA", "WPA2", or "WPA3".
value WEP Key Size¶
Key Size may be "40" or "104".
Key Size is in bits.
value WEP TX Key Index¶
TX Key Index may be "1", "2", "3" or "4".
value WEP Key <instance> Key¶
<instance> may range from 1 to 4.
Key may contain up to 13 bytes.
Set the Key value in hex, 5 or 13 bytes according to Key Size 40 or 104 bits respectively.
value WPAx Authentication¶
Authentication may be "PSK" or "8021X".
value WPAx IEEE 80211r¶
IEEE 80211r may be "Enabled" or "Disabled".
value WPAx Roam over DS¶
Roam over DS may be "Enabled" or "Disabled".
value WPAx Key Type¶
Key Type may be "Passphrase" or "Hex".
value WPAx Passphrase¶
Passphrase may contain up to 63 characters.
value WPAx Key¶
Key may contain up to 32 bytes.
Set the Key value in hex.
value WPAx IEEE 8021X¶
IEEE 8021X may be "EAP-TLS", "EAP-TTLS", "PEAP", "FAST" or "LEAP".
value WPAx Username¶
Username may contain up to 63 characters.
value WPAx Password¶
Password may contain up to 63 characters.
value WPAx Credentials¶
Credentials may contain up to 30 characters.
value WPAx EAP-TTLS Option¶
EAP-TTLS Option may be "EAP-MSCHAPV2", "MSCHAPV2", "MSCHAP", "CHAP", "PAP" or "EAP-MD5".
value WPAx PEAP ver¶
PEAP ver may be "0" or "1".
value WPAx PEAP Option¶
PEAP Option may be "EAP-MSCHAPV2", "EAP-MD5" or "EAP-TLS".
value WPAx PEAP Credentials¶
PEAP Credentials may contain up to 30 characters.
value WPAx FAST Option¶
FAST Option may be "MD5", "MSCHAPV2" or "GTC".
value WPAx Encryption¶
Encryption may contain combinations of "CCMP" or "TKIP".
"WPA" requires "TKIP", and only "TKIP".
"WPA2" requires "CCMP" and/or "TKIP".
configitem Advanced¶
value TX Power Maximum¶
TX Power Maximum has units of dBm.
TX Power Maximum governs the power output of the WLAN radio.
value Power Management¶
Power Management may be "Enabled" or "Disabled".
value PM Interval¶
PM Interval has units of beacons (100 ms each).
configgroup XML Import Control¶
configitem Restore Factory Configuration¶
value¶
Restore Factory Configuration may be "Enabled" or "Disabled".
configitem Reboot¶
value¶
Reboot may be "Enabled" or "Disabled".
configitem Missing Values¶
value¶
Missing Values may be "Unchanged" or "Set to Default".
configitem Delete WLAN Profiles¶
value¶
Delete WLAN Profiles may be "Enabled" or "Disabled".
configitem WLAN Profile delete¶
value name¶
name may contain up to 35 characters.
configitem DHCPv6 Client State¶
value¶
**DHCPv6 Client State** may contain one byte.
configitem DHCPv6 Client Record¶
value¶
DHCPv6 Client Record may contain up to 240 bytes.
configgroup AES Credential¶
Each AES Credential holds a secret Encrypt Key and Decrypt Key for secure communication.
configitem Encrypt Key¶
value¶
Encrypt Key may contain up to 32 bytes.
The Encrypt Key is used for encrypting outgoing data.
The Key is 16, 24, or 32 bytes in length. Any Key entered that is less than one of these is padded with zeroes. A byte specification comprises two nibble specifications with no intervening space. A nibble specification is a single digit from 0 to 9 or from "a" to "f" (representing 10 through 15).
Example Hexadecimal key: 12 34 56 78 9a bc de f0 01 02 03 04 05 06 07 08
To remove the Key, set it blank.
Note that the Key is a shared secret so it must be known by both sides of the connection and kept secret.
configitem Decrypt Key¶
value¶
Decrypt Key may contain up to 32 bytes.
The Decrypt Key is used for decrypting incoming data.
The Key is 16, 24, or 32 bytes in length. Any Key entered that is less than one of these is padded with zeroes. A byte specification comprises two nibble specifications with no intervening space. A nibble specification is a single digit from 0 to 9 or from "a" to "f" (representing 10 through 15).
Example Hexadecimal key: 12 34 56 78 9a bc de f0 01 02 03 04 05 06 07 08
To remove the Key, set it blank.
Note that the Key is a shared secret so it must be known by both sides of the connection and kept secret.
configgroup Azure¶
These settings pertain to Azure IoT connection information. Only one line can be assigned to the Azure IoT protocol.
configitem State¶
value¶
State may be "Enabled" or "Disabled".
"Disabled" turns Azure IoT off.
"Enabled" turns Azure IoT on.
configitem Hub Name¶
value¶
Hub Name may contain up to 64 characters.
The Hub Name created through the Azure portal.
configitem Device ID¶
value¶
Device ID may contain up to 128 characters.
The Device ID of the device.
configitem Security¶
value¶
Security may be "Security Keys" or "X.509 Certificate".
The Security type.
configitem SAS Token¶
value¶
SAS Token may contain up to 256 characters.
SAS Token (Shared Access Signature) is applicable when Security is set to "Security Keys". The SAS Token incorporates all of the information necessary to grant controlled access to a storage resource.
configitem Credential Name¶
value¶
Credential Name may contain up to 256 characters.
Credential Name is applicable when Security is set to "X.509 Certificate". It is the name of the credential to be found in TLS Credentials.
configitem MQTT Local Port¶
value¶
Blank the value for "<Random>".
configitem Receive Buffer¶
value¶
Receive Buffer has units of bytes.
Receive Buffer sets the allowed maximum size of device message that can be received from Azure.
Watch out in the tlog for the critical error message, "MQTT received xxxx bytes, but buffer is yyyy" Set Receive Buffer to have sufficient capacity for your application.
WARNING: Do not make the Receive Buffer larger than needed. The device may become unstable and crash without sufficient memory. Also consider removing unneeded modules.
configitem Reply Buffer¶
value¶
Reply Buffer has units of bytes.
Reply Buffer sets the allowed maximum size of the device reply to Azure.
Watch out on the Azure side for an error reply, "Needed xxx bytes; Reply Buffer capacity is yyy bytes." Set Reply Buffer to have sufficient capacity for your application.
WARNING: Do not make the Reply Buffer larger than needed. The device may become unstable and crash without sufficient memory. Also consider removing unneeded modules.
configgroup Bluetooth¶
These settings pertain to Bluetooth.
configitem State¶
value¶
State may be "Enabled" or "Disabled".
"Disabled" turns Bluetooth off.
"Enabled" turns Bluetooth on.
configitem Device Name¶
value¶
Device Name may contain up to 25 characters.
This is the Device Name provided to other Bluetooth devices through device discovery.
The Device Name defaults to model and serial number, and if made blank, will revert to this default.
NOTE: Changing the Device Name requires a reboot to take effect.
configitem Device Class¶
value¶
Device Class may contain up to 3 bytes.
configitem Background Scanning¶
value¶
Background Scanning may be "Enabled" or "Disabled".
This setting enables or disables background scanning, including both Bluetooth Low Energy (BLE) scanning and inquiry scanning for BR/EDR (sometimes referred to as classic Bluetooth) devices.
configitem Allow Discovery¶
value¶
Allow Discovery may be "No" or "Yes".
This setting determines whether the device will respond to inquiry scans.
configitem Allow Connections¶
value¶
Allow Connections may be "No" or "Yes".
This setting determines whether the device will accept connections.
Note: Disabling this setting means that any SDP discovery from another device will fail.
configitem Enable SPP Server¶
value¶
Enable SPP Server may be "No" or "Yes".
This setting determines whether the Serial Port Profile (SPP) server is enabled.
configitem SPP Service Channel¶
value¶
This setting defines the RFCOMM channel number for the Serial Port Profile (SPP) server. Service Channels can range from 1 to 30.
configitem Enable BLE Peripheral¶
value¶
Enable BLE Peripheral may be "No" or "Yes".
This setting enables or disables BLE Peripheral functionality. If enabled, the device will respond to BLE scans, and will run general advertisements.
configitem Lantronix Provisioning Server¶
value¶
Lantronix Provisioning Server may be "Enabled" or "Disabled".
This setting enables or disables the Lantronix BLE Provisioning Server.
configitem BLE Peripheral Device Name¶
value¶
BLE Peripheral Device Name may contain up to 25 characters.
This setting allows the device name used in BLE advertisements to be configured differently than the device name used for device discovery.
BLE advertisements are used by the Lantronix Provisioning Server.
Like the Device Name used for device discovery, this setting defaults to model and serial number, and if made blank, will revert to this default.
configgroup BLE Beacon Scanner¶
The XML instance may be "1", "SPP_1", "SPP_2", "SPP_3", "Virtual_1" or "Virtual_2".
These settings pertain to the BLE Beacon Scanner line protocol.
configitem Type¶
value¶
Type may contain combinations of "iBeacon".
configitem Transmit Mode¶
value¶
Transmit Mode may be "Disable", "Always", "Any Character" or "Start and Stop Characters".
The BLE Beacon Scanner can be configured to transmit depending on various conditions:
Disable: Never transmit.
Always: Always transmit.
Any Character: Start transmitting when any character is read on the line. Transmission will continue until any character is subsequently read on the line.
Start and Stop Characters: Start transmitting when a specific character is read on the line. Transmission will continue until a specific character is subsequently read on the line.
configitem Start Character¶
value¶
Start Character may contain one byte.
A control character <control>J, for example, counts as one.
A control character can be input in alternate forms:
- \17 (decimal)
- 0x11 (hexadecimal)
- <control>Q (control)
The Start Character is a specific value that must be read on the line before transmission can begin.
configitem Stop Character¶
value¶
Stop Character may contain one byte.
A control character <control>J, for example, counts as one.
A control character can be input in alternate forms:
- \17 (decimal)
- 0x11 (hexadecimal)
- <control>Q (control)
The Start Character is a specific value that must be read on the line before transmission will stop.
configitem Output Format¶
value¶
Output Format may contain up to 53 characters.
The Output Format specifies how the beacon information will be patterned when transmitted on the line.
There are four main portions of the beacon that can be used in the Output Format:
<UUID>: The beacon UUID.
<MAJOR>: The major number of the beacon.
<MINOR>: The minor number of the beacon.
<RSSI>: The RSSI value of the message containing the beacon.
The Output Format must contain at least one of the four beacon portions. In addition, there is some room in the format string for ancillary characters that can be used for separators or other formatting.
To return to the default Output Format, clear this setting.
configgroup Bridge¶
Bridging allows a "bridged machine" to send and receive frames via wlan0 or ap0.
NOTE: A reboot is required for configuration changes to take effect.
configitem Interface¶
value¶
Interface may be "Disabled", "wlan0" or "ap0".
"Disabled" turns bridging off.
"wlan0" turns bridging on directed to and from wlan0. Configuration for IP Addressing, Static or Dynamic, must match between the bridged machine and this device.
"ap0" turns bridging on directed to and from ap0.
configitem Ethernet¶
value Mode¶
Mode may be "Disabled", "Dynamic" or "Static".
"Disabled" turns Ethernet bridging off.
"Dynamic" turns Ethernet bridging on using the source MAC Address of the most recent received packet.
"Static" turns Ethernet bridging on using the MAC Address configured here.
value MAC Address¶
MAC Address may contain up to 6 bytes.
Only frames from the bridged machine bearing this MAC Address as source will be forwarded to the selected Interface.
Both ap0 and wlan0 will adopt this MAC Address, as the radio only handles a single MAC Address for all of its traffic.
value IGMP <instance> IP Address¶
<instance> may range from 1 to 6.
IP Address may contain up to 15 characters.
Each IGMP IP Address is a multicast address allowed to pass through the bridge.
configgroup CLI Server¶
These settings pertain to the CLI Server. Changes take effect immediately.
configitem Inactivity Timeout¶
value¶
Inactivity Timeout has units of minutes, and/or hours.
Enter 0 for "<None>".
After this time period with no activity, the CLI Server will close the connection.
configitem Telnet¶
value Mode¶
Mode may be "Enabled" or "Disabled".
value Interface¶
Interface may be "Any", "ap0", "eth0" or "wlan0".
value Port¶
The CLI Server listens on this port for incoming Telnet connections.
configgroup Discovery¶
*The XML *instance may be "ap0", "eth0" or "wlan0".
These settings pertain to Discovery. Changes take effect immediately.
Query Port is a Lantronix discovery protocol server. It implements a simple proprietary discovery service on port 0x77FE (30718).
configitem Query Port¶
value State¶
State may be "Enabled" or "Disabled".
"Enabled" allows the device to be discovered.
"Disabled" prevents discovery from finding the device.
configgroup ConsoleFlow Device¶
These settings pertain to the ConsoleFlow management platform.
configitem State¶
value¶
State may be "Enabled" or "Disabled".
configitem Status Update Interval¶
value¶
Status Update Interval has units of minutes, hours, and/or days.
The Status Update Interval is the period of time that ConsoleFlow waits between updating device status to the cloud.
The Status Update Interval can be configured between 1 minute and 1 day (1440 minutes).
configitem Content Check Interval¶
value¶
Content Check Interval has units of hours, and/or days.
The Content Check Interval is the period of time that ConsoleFlow waits between checking the cloud for updates to firmware and configuration.
The Content Check Interval can be configured between 1 hour and 90 days (2160 hours).
configitem Apply Firmware Updates¶
value¶
Apply Firmware Updates may be "Enabled" or "Disabled".
configitem Apply Configuration Updates¶
value¶
Apply Configuration Updates may be "Never", "If Unchanged" or "Always".
If the If Unchanged option is selected, configuration updates will only be applied if the current configuration has not been locally modified.
configitem Reboot After Configuration Update¶
value¶
Reboot After Configuration Update may be "Enabled" or "Disabled".
If enabled, this setting will automatically reboot after a successful configuration upgrade.
The device will always reboot after a successful firmware upgrade.
configitem Device Name¶
value¶
Device Name may contain up to 63 characters.
The Device Name must be at least 2 characters long, and may contain alphanumeric, hyphen, or underscore characters (A-Z,a-z,0-9,-,_) only. The first and last characters must be alphanumeric.
configitem Device Description¶
value¶
Device Description may contain up to 63 characters.
The Device Description is optional.
configitem Additional Logging¶
value¶
Additional Logging may be "Enabled" or "Disabled".
When enabled, ConsoleFlow will provide more information in the Trouble Log.
configitem Active Connection¶
value¶
Active Connection may be "<numbe>>".
The Active Connection specifies which connection parameters will be used in communication with the cloud.
configitem Connection¶
The XML instance may range from 1 to 2.
The Connections define the parameters to use in communication with the cloud.
Up to 2 Connections can be defined, with the Active Connection selecting which will be used.
value Domain¶
Domain may contain up to 63 characters.
The Domain specifies the ConsoleFlow cloud host.
value Local Port¶
Blank the value for "<Random>".
The Local Port is random by default but can be overridden here.
Note: If you have bridging enabled, you will need to specify a non-random value here in order for ConsoleFlow to operate correctly.
configitem MQTT State¶
MQTT State may be "Enabled" or "Disabled".
This controls whether ConsoleFlow will use MQTT to communicate with the cloud.
Note: MQTT requires a persistent connection.
value MQTT Domain¶
MQTT Domain may contain up to 63 characters.
The MQTT Domain specifies the ConsoleFlow MQTT cloud host.
value MQTT Local Port¶
Blank the value for "<Random>".
The MQTT Local Port is random by default but can be overridden here.
Note: If you have bridging enabled, you will need to specify a non-random value here in order for ConsoleFlow to operate correctly.
configgroup ConsoleFlow Line¶
The XML instance may be "1", "gSPI_1", "gSPI_2", "gSPI_3", "gSPI_4", "SPP_1", "SPP_2", "SPP_3", "CDC_ACM", "HOST_CDC_ACM", "Virtual_1" or "Virtual_2".
These settings pertain to the ConsoleFlow management platform.
configitem State¶
value¶
State may be "Enabled" or "Disabled".
configitem Project Tag¶
value¶
Project Tag may contain up to 63 characters.
configitem Status Update Interval¶
value¶
Status Update Interval has units of minutes, hours, and/or days.
The Status Update Interval is the period of time that ConsoleFlow waits between updating device status to the cloud.
The Status Update Interval can be configured between 1 minute and 1 day (1440 minutes).
configitem Content Check Interval¶
value¶
Content Check Interval has units of hours, and/or days.
The Content Check Interval is the period of time that ConsoleFlow waits between checking the cloud for updates to firmware and configuration.
The Content Check Interval can be configured between 1 hour and 90 days (2160 hours).
configgroup GATT Server Custom Service¶
These settings pertain to each GATT Custom Service.
configitem Description¶
value¶
Description may contain up to 30 characters.
Description is an optional field that can add information to the service instance identifier.
configitem UUID¶
value¶
UUID may contain up to 36 characters.
This is the service UUID. The UUID is a 128-bit value specified in a string of 32 hexadecimal bytes.
UUIDs are typically formatted as follows: xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx
configitem Characteristic¶
The XML instance may range from 1 to 2.
This is a GATT Characteristic for the service. GATT characteristics are what actually communicate data in a GATT service.
Up to 2 characteristics can be defined per service. Characteristics are defined by a UUID and a set of properties.
value UUID¶
UUID may contain up to 36 characters.
This is the service characteristic UUID. The UUID is a 128-bit value specified in a string of 32 hexadecimal bytes.
UUIDs are typically formatted as follows: xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx
value Properties¶
Properties may contain combinations of "Readable" or "Writable".
Properties define the type of information and access that a characteristic provides. While GATT service characteristics support several different properties, only the "Readable" and "Writable" properties are available here for a custom GATT service.
NOTE: You must selected at least one property in order for service data to be accessible.
configitem Advertise¶
value¶
Advertise may be "No" or "Yes".
The device can only advertise one BLE service. If the Lantronix Provisioning Server is enabled, then it is the one service that is advertised.
If selected, this setting only applies if the Lantronix Provisioning Server is disabled.
configitem Interface¶
value¶
Interface may be "Disabled" or "Line Driver".
This service is not useable unless an interface has been selected.
If selected, the Line Driver interface creates a new Line instance for this service. The Line name will be in the format GATTS_[instance]. The device must be rebooted before the new Line instance can be used.
NOTE: You will likely need to completely refresh the Web Manager in order to see the new Line instance.
configgroup LPD¶
The XML instance must be "1".
These configurables are for the Line Printer Daemon (LPD).
configitem Banner¶
value¶
Banner may be "Enabled" or "Disabled".
Enabling Banner will force the banner page to be printed even if the incoming print job does not specify to do so.
configitem Binary¶
value¶
Binary may be "Enabled" or "Disabled".
Enabling Binary will pass the entire file to the printer without removing any characters. Disabled, only valid ascii and control characters are passed; all others are stripped. Valid control characters include the tab, linefeed, formfeed, backspace, and newline.
configitem SOJ Text¶
value¶
SOJ Text may contain up to 100 bytes.
Non-printable characters must be in decimal or hexadecimal form
enclosed in square braces and separated by commas.
To specify an open square brace, use two in a row.
Example: AB[255,0xFF]C[[D]
results in this string, where dots hold place of unprintable characters:
AB..C[D]
To send a Start Of Job (SOJ) string to the printer, enter the appropriate string.
configitem EOJ Text¶
value¶
EOJ Text may contain up to 100 bytes.
Non-printable characters must be in decimal or hexadecimal form
enclosed in square braces and separated by commas.
To specify an open square brace, use two in a row.
Example: AB[255,0xFF]C[[D]
results in this string, where dots hold place of unprintable characters:
AB..C[D]
To send an End Of Job (EOJ) string to the printer, enter the appropriate string.
configitem Formfeed¶
value¶
Formfeed may be "Enabled" or "Disabled".
Enabling Formfeed will force a formfeed to be sent to the printer at the end of each print job.
configitem Convert Newline¶
value¶
Convert Newline may be "Enabled" or "Disabled".
Enabling Convert Newline will convert single newlines and single carriage returns into DOS style carriage return + linefeed line endings; if carriage return and linefeed characters are already in the correct DOS line-ending order, they will remain unchanged.
configitem Queue Name¶
value¶
Queue Name may contain up to 32 characters.
A Queue Name may not contain white space.
configgroup Modbus¶
The XML instance may be "1", "SPP_1", "SPP_2", "SPP_3", "HOST_CDC_ACM", "Virtual_1" or "Virtual_2".
These settings pertain to Modbus in the device for the associated line.
configitem TCP Server State¶
value¶
TCP Server State may be "Enabled" or "Disabled".
"Disabled" turns Modbus off.
"Enabled" turns Modbus on.
configitem Port¶
value¶
Enter 0 for "<None>".
Port is required for the Modbus to accept a connection.
configitem Response Timeout¶
value¶
Response Timeout has units of milliseconds.
Response Timeout is the timeout waiting for a response from slave device.
configgroup Modem Emulation¶
The XML instance may be "1", "gSPI_1", "gSPI_2", "gSPI_3", "gSPI_4", "SPP_1", "SPP_2", "SPP_3", "CDC_ACM", "HOST_CDC_ACM", "Virtual_1" or "Virtual_2".
Connections can be initiated and accepted using Modem "AT" commands incoming from the Serial Line.
configitem Listen Port¶
value¶
Blank the value for "<None>".
Specify a Listen Port to accept connections on.
configitem Connect Local Port¶
value¶
Blank the value for "<Random>".
Optionally specify a Connect Local Port for ATD connections. Note that this is necessary for operation while bridging.
configitem Echo Pluses¶
value¶
Echo Pluses may be "Enabled" or "Disabled".
"Enabled" means pluses will be echoed back during a "pause +++ pause" escape sequence on the Serial Line.
configitem Echo Commands¶
value¶
Echo Commands may be "Enabled" or "Disabled".
"Enabled" (ATE1) means characters read on the Serial Line will be echoed while the Line is in Modem Command Mode.
configitem Verbose Response¶
value¶
Verbose Response may be "Enabled" or "Disabled".
"Enabled" (ATQ0) means Modem Response Codes are sent out on the Serial Line.
configitem Response Type¶
value¶
Response Type may be "Text" or "Numeric".
Either "Text" (ATV1) or "Numeric" (ATV0) representation for the Modem Response Codes are sent out on the Serial Line.
configitem Error Unknown Commands¶
value¶
Error Unknown Commands may be "Enabled" or "Disabled".
"Enabled" (ATU0) means ERROR is returned on the Serial Line for unrecognized AT commands.
"Disabled" (ATU1) means OK is returned for unrecognized AT commands.
configitem Incoming Connection¶
value¶
Incoming Connection may be "Disabled", "Automatic" or "Manual".
"Disabled" (ATS0=0) will refuse to answer.
"Automatic" (ATS0=1) will answer immediately.
"Manual" (ATS0=2 or higher) may be answered via the ATA command after an incoming RING.
configitem Connect String¶
value¶
Connect String may contain up to 30 characters.
The Connect String is a customized string that is sent to the Serial Line with the CONNECT Modem Response Code.
configitem Display Remote IP¶
value¶
Display Remote IP may be "Enabled" or "Disabled".
"Enabled" means the incoming RING sent on the Serial Line is followed by the IP address of the caller.
configgroup Monitor Initialization¶
These settings pertain to Monitor Initialization in the device.
Monitor will process any initialization message before it starts polling or process any control message. Response captured during initialization will be overwritten by any poll or control response.
configitem Initial Delay¶
value¶
Initial Delay has units of milliseconds.
Sets Initial Delay waited before monitor start processing any initialization message.
configitem Message¶
*The XML *instance may range from 1 to 4.
value Command¶
Command may contain up to 32 bytes.
Non-printable characters must be in decimal or hexadecimal form enclosed in square braces and separated by commas. To specify an open square brace, use two in a row. Example: AB[255,0xFF]C[[D]
results in this string, where dots hold place of unprintable characters: AB..C[D]
Sets the Command in binary format.
Binary format takes printable characters (e.g. 'abc' for characters 'a', 'b' and 'c') or binary string (e.g. [0xa, 0xd] for line feed and carriage return).
value End Character¶
End Character may contain one byte.
A control character <control>J, for example, counts as one.
A control character can be input in alternate forms:
- \17 (decimal)
- 0x11 (hexadecimal)
- <control>Q (control)
Sets the End Character to indicate end of response.
Response is ended by any configured End Character, Length OR Timeout.
value Length¶
Length has units of bytes.
Sets the Length of response.
Response is ended by any configured End Character, Length OR Timeout.
value Timeout¶
Timeout has units of milliseconds.
Blank the value for "<Minimum>".
Sets the Timeout to receive response.
Response is ended by any configured End Character, Length OR Timeout.
configgroup Monitor Control¶
These settings pertain to Monitor Control in the device.
Control Message will be processed after receiving status action Send. Response will overwrite any response captured during initialization or poll. Response must be read before sending another status action Send or buffer will be reset.
configitem Message¶
*The XML *instance may range from 1 to 4.
value Command¶
Command may contain up to 32 bytes.
Non-printable characters must be in decimal or hexadecimal form enclosed in square braces and separated by commas. To specify an open square brace, use two in a row. Example: AB[255,0xFF]C[[D]
results in this string, where dots hold place of unprintable characters: AB..C[D]
Sets the Command in binary format.
Binary format takes printable characters (e.g. 'abc' for characters 'a', 'b' and 'c') or binary string (e.g. [0xa, 0xd] for line feed and carriage return).
value End Character¶
End Character may contain one byte.
A control character <control>J, for example, counts as one.
A control character can be input in alternate forms:
- \17 (decimal)
- 0x11 (hexadecimal)
- <control>Q (control)
Sets the End Character to indicate end of response.
Response is ended by any configured End Character, Length OR Timeout.
value Length¶
Length has units of bytes.
Sets the Length of response.
Response is ended by any configured End Character, Length OR Timeout.
value Timeout¶
Timeout has units of milliseconds.
Blank the value for "<Minimum>".
Sets the Timeout to receive response.
Response is ended by any configured End Character, Length OR Timeout.
configgroup Monitor Poll¶
These settings pertain to Monitor Poll in the device.
Poll Message will be processed periodically. Response will overwrite any response captured during initialization or poll.
configitem Message¶
*The XML *instance may range from 1 to 4.
value Command¶
Command may contain up to 32 bytes.
Non-printable characters must be in decimal or hexadecimal form enclosed in square braces and separated by commas. To specify an open square brace, use two in a row. Example: AB[255,0xFF]C[[D]
results in this string, where dots hold place of unprintable characters: AB..C[D]
Sets the Command in binary format.
Binary format takes printable characters (e.g. 'abc' for characters 'a', 'b' and 'c') or binary string (e.g. [0xa, 0xd] for line feed and carriage return).
value End Character¶
End Character may contain one byte.
A control character <control>J, for example, counts as one.
A control character can be input in alternate forms:
- \17 (decimal)
- 0x11 (hexadecimal)
- <control>Q (control)
Sets the End Character to indicate end of response.
Response is ended by any configured End Character, Length OR Timeout.
value Length¶
Length has units of bytes.
Sets the Length of response.
Response is ended by any configured End Character, Length OR Timeout.
value Timeout¶
Timeout has units of milliseconds.
Blank the value for "<Minimum>".
Sets the Timeout to receive response.
Response is ended by any configured End Character, Length OR Timeout.
configitem Delay¶
value¶
Delay has units of seconds, minutes, hours, and/or days.
Sets Delay waited before monitor starts processing all poll messages again. 0 means poll messages are sent only once.
configgroup Monitor Filter¶
These settings pertain to Monitor Filter in the device.
Filter settings will be applied to all received response. Filter results can be used to feed another filter or use as Data Reference.
configitem Rule¶
*The XML *instance may range from 1 to 4.
value Source¶
Source may contain up to 6 characters.
Sets the Source in dot number format.
Source defines the input of a filter. E.g. If the source of this Filter is the second trunk of data created by filter 1, Source must be set to "1.2". A Source of "0" indicates the raw response.
Dot number format could be "0" or two numbers separated by a dot (e.g. "1.2").
value Mode¶
Mode may be "All", "Delimiters" or "Binary".
"All" makes filter ouput to be a duplicate of input.
"Delimiters" filter breaks input up to 8 trunks separated by Binary String. Each trunk will not contain the delimiters.
"Binary" filter breaks input into 3 trunks according to Offset and Length.
value Delimiter <instance> Binary String¶
<instance> may range from 1 to 2.
Binary String may contain up to 6 bytes.
Non-printable characters must be in decimal or hexadecimal form enclosed in square braces and separated by commas. To specify an open square brace, use two in a row. Example: AB[255,0xFF]C[[D]
results in this string, where dots hold place of unprintable characters: AB..C[D]
Sets Binary String delimiter in binary format.
Delimiters break input up to 8 trunks separated by (but not containing) delimiters. A delimiter is recognized if any of the Binary String is completely matched.
Binary format takes printable characters (e.g. 'abc' for characters 'a', 'b' and 'c') or binary string (e.g. [0xa, 0xd] for line feed and carriage return).
value Start Index¶
Sets Start Index to indicate when Delimiters filter starts breaking input into trunks.
value Offset¶
Offset has units of bytes.
Sets Offset for the size of the first trunk of data created by Binary Filter.
value Length¶
Length has units of bytes.
Sets Length for the size of the second trunk of data created by Binary Filter. The third trunk of data created by Binary Filter will contain the rest of input.
configgroup Monitor Data¶
These settings pertain to Monitor Data in the device.
Data configured here will be accessible through the status of Monitor.
configitem Selector¶
*The XML *instance may range from 1 to 8.
value Name¶
Name may contain up to 16 characters.
Sets Name to enable the data selector.
value Response¶
Blank the value for "<None>".
Sets Response instance to select the source of data. Response instance corresponds to Poll or Control Message instance.
value Reference¶
Reference may contain up to 6 characters.
Sets the Reference in dot number format.
Reference selects the output of Monitor Filter. E.g. If data should select the second trunk of data created by filter 1, Reference must be set to "1.2". A Reference of "0" indicates the raw response.
Dot number format could be "0" or two numbers separated by a dot (e.g. "1.2").
configgroup NTP¶
These configurables are for Simple NTP (SNTP).
configitem Server Hostname¶
value¶
Server Hostname may contain up to 128 characters.
The Server Hostname is the name or IP address of an NTP server.
configitem Sync Time¶
value¶
Sync Time has units of seconds, minutes, and/or hours.
The NTP client waits Sync Time after successful update before querying again.
configgroup SNMP¶
These configurables are for Simple Network Management Protocol version 2 (SNMPv2) Agent.
configitem State¶
value¶
State may be "Enabled" or "Disabled".
By default this is disabled, This enables the SNMPv2 agent on the listen network.
configitem Listen Interface¶
value¶
Listen Interface may be "ap0", "eth0" or "wlan0".
configitem Community Read¶
value¶
Community Read may contain up to 64 characters.
A string value to read the SNMP variables, By default this is set public.
configitem Community Write¶
value¶
Community Write may contain up to 64 characters.
A string value to read the SNMP variables, By default this is set private.
configitem System Contact¶
value¶
System Contact may contain up to 64 characters.
configitem System Name¶
value¶
System Name may contain up to 64 characters.
configitem System Description¶
value¶
System Description may contain up to 64 characters.
configitem System Location¶
value¶
System Location may contain up to 64 characters.
configitem Traps¶
value State¶
State may be "Enabled" or "Disabled".
By default this is disabled, This enables to send the predefined traps to specified destinations.
value Primary Destination¶
Primary Destination may contain up to 64 characters.
value Secondary Destination¶
Secondary Destination may contain up to 64 characters.
configitem Extended Agent¶
value IP Address¶
IP Address may contain up to 31 characters.
value Port¶
Blank the value for "<None>".
configgroup TLS Credential¶
Manages certificates for TLS clients and servers.
NOTE: Minimum accepted RSA key size is 2048 bits.
configitem Protocols¶
value¶
Protocols may contain combinations of "TLS1.0", "TLS1.1" or "TLS1.2".
However only these combinations are accepted:
- TLS1.0
- TLS1.1
- TLS1.2
- TLS1.1, TLS1.2
- TLS1.0, TLS1.1, TLS1.2
configitem Private Key¶
value¶
Private Key may contain up to 4000 characters.
The Private Key is input and stored in PEM format.
configitem Certificate¶
value¶
Certificate may contain up to 4000 characters.
The Certificate is input and stored in PEM format.
configitem Higher Authority¶
*The XML *instance may range from 1 to 3.
value Certificate¶
Certificate may contain up to 4000 characters.
The Certificate is input and stored in PEM format.
When an incoming connection is attempted, the TLS Server will present Higher Authority certificates in its signing chain.
configitem Trusted Authority¶
*The XML *instance may range from 1 to 5.
value Certificate¶
Certificate may contain up to 4000 characters.
The Certificate is input and stored in PEM format.
TLS Client will accept a server presenting any of these Trusted Authority certificates.
Mutual Authentication
If any Trusted Authority certificate is present, TLS Server will require clients to match; otherwise clients are unrestricted.
configgroup Bluetooth_SPP Master¶
These settings pertain to the SPP Line configuration with the device server in the Bluetooth master role.
configitem Device¶
The XML instance must be .
Displayed here will be any devices that have been previously assigned to SPP Lines as well as any currently bonded and connected devices.
Each SPP Line can only be connected to a single device.
If a device is assigned to an SPP Line and subsequently forgotten, the line assignment will not be remembered.
value SPP Line¶
SPP Line may be "Unassigned" or "SPP_
Select the SPP Line to connect to a particular Bluetooth slave device, or select Unassigned to remove the connection between a previously connected slave device and its SPP Line.
Protocol selection for SPP Lines is available as part of Line configuration.
configgroup Bluetooth_SPP Slave¶
Choose an SPP Line to connect to the Bluetooth master device. Note that the SPP Line assigned here will always be connected to whichever Bluetooth device is currently bonded as a master device to this slave.
Each SPP Line can only be connected to a single device.
configitem SPP Line¶
value¶
SPP Line may be "Unassigned" or "SPP_<number>".
Select the SPP Line to connect to the Bluetooth master device, or select Unassigned to remove the connection between the master device and its SPP Line.
Protocol selection for SPP Lines is available as part of Line configuration.
configgroup Tunnel Accept¶
The XML instance may be "1", "SPP_1", "SPP_2", "SPP_3", "Virtual_1" or "Virtual_2".
Tunnel Accept controls how a tunnel behaves when a connection attempt originates from the network.
configitem Mode¶
value¶
Mode may be "Disable", "Always", "Any Character", "Start Character" or "Modem Control Asserted".
An Accept Tunnel can be started in a number of ways, according to its Mode:
"Disabled": never started.
"Always": always started.
"Any Character": started when any character is read on the Serial Line.
"Start Character": started when the Start Character is read on the Serial Line.
"Modem Control Asserted": started when the Modem Control pin is asserted on the Serial Line.
configitem Local Port¶
value¶
Blank the value for "<None>".
Local Port is required for the Tunnel to accept a connection.
configitem Multiple Connections¶
value¶
Multiple Connections may be "Enabled" or "Disabled".
Enable Multiple Connections to allow up to 4 connections. This can be useful if the network side is only receiving data.
Disable Multiple Connections for applications requiring sequential access. This is normally required if the network side is sending data.
configitem Protocol¶
value¶
Protocol may be "TCP", "TCP AES" or "TLS".
configitem Credential¶
value¶
Credential may contain up to 30 characters.
The Credential named here must belong to the selected Protocol.
Configure the named Credential on its seperate page. A Credential typically contains whatever keys, certificates, passwords, or usernames that are required for connection using the selected Protocol.
configitem Start Character¶
value¶
Start Character may contain one byte.
A control character <control>J, for example, counts as one.
A control character can be input in alternate forms:
- \17 (decimal)
- 0x11 (hexadecimal)
- <control>Q (control)
When the Start Character is received on the Serial Line, it enables the tunnel to listen for a network connection.
configitem Flush Start Character¶
value¶
Flush Start Character may be "Enabled" or "Disabled".
"Enabled" prevents forwarding of a start character from the Line into the network.
"Disabled" allows forwarding of a start character from the Line into the network.
configitem Flush Line¶
value¶
Flush Line may be "Enabled" or "Disabled".
Flush Line applies at the time when a connection is accepted from the network.
"Enabled" means any buffered characters from the Serial Line will be discarded when a connection is accepted.
"Disabled" means any characters received on the Serial Line will be buffered and sent after a connection is accepted.
configitem Block Line¶
value¶
Block Line may be "Enabled" or "Disabled".
"Enabled" (the debug setting) means incoming characters from the Serial Line will NOT be forwarded to the network. Instead, they will be buffered and will eventually flow off the Serial Line if hardware or software flow control is configured.
"Disabled" (the normal setting) means incoming characters from the Serial Line are sent on into the network. Any buffered characters are sent first.
configitem Block Network¶
value¶
Block Network may be "Enabled" or "Disabled".
"Enabled" (the debug setting) means incoming characters from the network will NOT be forwarded to the Serial Line. Instead, they will be buffered and will eventually flow off the network side.
"Disabled" (the normal setting) means incoming characters from the network are sent on into the Serial Line. Any buffered characters are sent first.
configitem Password¶
value¶
Password may contain up to 31 characters.
The Password must contain only alphanumeric characters and punctuation. When set, clients must send the correct password string to the unit within 30 seconds from opening network connection in order to enable data transmission. The password sent to the unit must be terminated with one of the following:
- 0A (Line Feed)
- 00 (Null)
- 0D 0A (Carriage Return / Line Feed)
- 0D 00 (Carriage Return / Null)
If Prompt for Password is "Enabled", the user will be prompted for the password upon connection.
configitem Prompt for Password¶
value¶
Prompt for Password may be "Enabled" or "Disabled".
configgroup Tunnel Line¶
The XML instance may be "1", "SPP_1", "SPP_2", "SPP_3", "Virtual_1" or "Virtual_2".
The Line Configuration applies to the Serial Line interface.
configitem DTR¶
value¶
DTR may be "Asserted while connected", "Continuously asserted" or "Unasserted".
The DTR options select the conditions in which the Data Terminal Ready control signal on the Serial Line is asserted.
"Asserted while connected" causes DTR to be asserted whenever either a connect or an accept mode tunnel connection is active.
configgroup Tunnel Connect¶
The XML instance may be "1", "SPP_1", "SPP_2", "SPP_3", "Virtual_1" or "Virtual_2".
Tunnel Connect controls how a tunnel behaves when a connection attempt originates locally.
configitem Mode¶
value¶
Mode may be "Disable", "Always", "Any Character", "Start Character" or "Modem Control Asserted".
A Connect Tunnel can be started in a number of ways, according to its Mode:
"Disabled": never started.
"Always": always started.
"Any Character": started when any character is read on the Serial Line.
"Start Character": started when the Start Character is read on the Serial Line.
"Modem Control Asserted": started when the Modem Control pin is asserted on the Serial Line.
configitem Start Character¶
value¶
Start Character may contain one byte.
A control character <control>J, for example, counts as one.
A control character can be input in alternate forms:
- \17 (decimal)
- 0x11 (hexadecimal)
- <control>Q (control)
When the Start Character is received on the Serial Line, it connects the tunnel.
configitem Flush Start Character¶
value¶
Flush Start Character may be "Enabled" or "Disabled".
"Enabled" prevents forwarding of a start character from the Line into the network.
"Disabled" allows forwarding of a start character from the Line into the network.
configitem Host¶
*The XML *instance may range from 1 to 4.
value Address¶
Address may contain up to 50 characters.
The Host Address is required to enable a Connect Tunnel.
It designates the address of the remote host to connect to.
Either a DNS address or an IP address may be provided.
If your Protocol is UDP based and you want to listen rather than connect: Leave Host Port set to <None> and set Host Address to the Interface name you want to listen to ("ap0" or "wlan0").
value Port¶
Blank the value for "<None>".
The Host Port is required to enable a Connect Tunnel.
It designates the TCP or UDP port on the remote host to connect to.
value Protocol¶
Protocol may be "TCP", "TCP AES", "TLS" or "UDP".
value Credential¶
Credential may contain up to 30 characters.
The Credential named here must belong to the selected Protocol.
Configure the named Credential on its seperate page. A Credential typically contains whatever keys, certificates, passwords, or usernames that are required for connection using the selected Protocol.
value Initial Send¶
Initial Send may contain up to 32 characters.
The Initial Send string, if present, is sent out the network before any other data when the connection is established.
value Local Port¶
Blank the value for "<Random>".
The Local Port is by default random but can be overridden.
Note that a non-random Local Port is required for operation over a bridged interface.
value Reception¶
Reception may be "Restricted" or "Unrestricted".
"Restricted" will discard any received UDP packets whose from address and port do not match the designated Host Address and Port. In UDP listen mode, the remote address and port of the first received packet are taken as designated until the socket is closed.
"Unrestricted" accepts any UDP packets directed to the Local Port regardless of where they came from.
configitem Connections¶
value¶
Connections may be "Sequential", "Simultaneous" or "Round-Robin".
Connections controls how multiple hosts shall be used with a Connect Tunnel.
"Sequential" means the tunnel will start with host 1 and attempt each host in sequence until a connection is accepted.
"Simultaneous" means the tunnel will connect to all of the hosts that accept a connection.
"Round-Robin" means the tunnel connection attempts start with the host after whichever host had previously connected.
configitem Reconnect Time¶
value¶
Reconnect Time has units of seconds, minutes, and/or hours.
The Reconnect Time specifies how long to wait before trying to reconnect to the remote host after a previous attempt failed or the connection was closed. Set to '0' to disable reconnect.
Blank the display field to restore the default.
configitem Flush Line¶
value¶
Flush Line may be "Enabled" or "Disabled".
Flush Line applies at the time when a connection is established to the network.
"Enabled" means any buffered characters from the Serial Line will be discarded when a connection is established.
"Disabled" means any characters received on the Serial Line will be buffered and sent after a connection is established.
configitem Block Line¶
value¶
Block Line may be "Enabled" or "Disabled".
"Enabled" (the debug setting) means incoming characters from the Serial Line will NOT be forwarded to the network. Instead, they will be buffered and will eventually flow off the Serial Line if hardware or software flow control is configured.
"Disabled" (the normal setting) means incoming characters from the Serial Line are sent on into the network. Any buffered characters are sent first.
configitem Block Network¶
value¶
Block Network may be "Enabled" or "Disabled".
"Enabled" (the debug setting) means incoming characters from the network will NOT be forwarded to the Serial Line. Instead, they will be buffered and will eventually flow off the network side.
"Disabled" (the normal setting) means incoming characters from the network are sent on into the Serial Line. Any buffered characters are sent first.
configgroup Tunnel Disconnect¶
The XML instance may be "1", "SPP_1", "SPP_2", "SPP_3", "Virtual_1" or "Virtual_2".
These settings relate to Disconnecting a Tunnel.
configitem Stop Character¶
value¶
Stop Character may contain one byte.
A control character <control>J, for example, counts as one.
A control character can be input in alternate forms:
- \17 (decimal)
- 0x11 (hexadecimal)
- <control>Q (control)
When the Stop Character is received on the Serial Line, it disconnects the tunnel.
Disable the Stop Character by blanking the field to set it to <None>.
configitem Flush Stop Character¶
value¶
Flush Stop Character may be "Enabled" or "Disabled".
"Enabled" prevents forwarding of a stop character from the Line into the network.
"Disabled" allows forwarding of a stop character from the Line into the network.
configitem Modem Control¶
value¶
Modem Control may be "Enabled" or "Disabled".
"Enabled" means disconnect when the Modem Control pin is not asserted on the Serial Line.
configitem Timeout¶
value¶
Timeout has units of milliseconds.
Blank the value for "<Disabled>".
Timeout enables disconnect after the tunnel is idle for a specified number of milliseconds.
configitem Flush Line¶
value¶
Flush Line may be "Enabled" or "Disabled".
"Enabled" means flush the Serial Line when the Tunnel is disconnected.
configgroup Tunnel Packing¶
The XML instance may be "1", "SPP_1", "SPP_2", "SPP_3", "Virtual_1" or "Virtual_2".
When Tunneling, instead of sending data on the network immediately after being read on the Serial Line, the data can be Packed (queued) and sent in larger chunks.
configitem Mode¶
value¶
Mode may be "Disable", "Timeout" or "Send Character".
"Disable" means data is not packed.
"Timeout" means data is sent only after a timeout occurs.
"Send Character" means data is sent when the Send Character is read on the Serial Line.
configitem Timeout¶
value¶
Timeout has units of milliseconds.
If the oldest byte of queued data has been waiting for Timeout milliseconds, the queued data will be sent on the network immediately.
configitem Threshold¶
value¶
Threshold has units of bytes.
If the number of bytes of queued data reaches the Threshold, the queued data will be sent on the network immediately.
configitem Send Character¶
value¶
Send Character may contain one byte.
A control character <control>J, for example, counts as one.
A control character can be input in alternate forms:
- \17 (decimal)
- 0x11 (hexadecimal)
- <control>Q (control)
If used, the Send Character is a single printable character or a control character that, when read on the Serial Line, forces the queued data to be sent on the network immediately.
configitem Flush Send Character¶
value¶
Flush Send Character may be "Enabled" or "Disabled".
"Enabled" means the Send Character will NOT be sent from the Serial Line to the network.
"Disabled" means the Send Character WILL be forwarded from the Serial Line to the network.
configitem Trailing Character¶
value¶
Trailing Character may contain one byte.
A control character <control>J, for example, counts as one.
A control character can be input in alternate forms:
- \17 (decimal)
- 0x11 (hexadecimal)
- <control>Q (control)
The Trailing Character is an optional single printable character or control character that is injected into the outgoing data stream right after the Send Character.
Disable the Trailing Character by blanking the field to set it to <None>.
configgroup USB Device¶
configitem State¶
value¶
State may be "Enabled" or "Disabled".
configgroup USB Host¶
configitem State¶
value¶
State may be "Enabled" or "Disabled".
configgroup Custom¶
User custom configuration values are stored under this group.
configitem Item¶
value Value¶
Value may contain up to 63 characters.
Sets a custom configurable text Value of an Item. The Item <instance> is the name of this value.